{"id":5678,"date":"2022-01-03T12:01:48","date_gmt":"2022-01-03T12:01:48","guid":{"rendered":"https:\/\/www.clpu.es\/publications\/recirculated-wave-undulators-for-compact-fels\/"},"modified":"2025-02-03T08:50:47","modified_gmt":"2025-02-03T08:50:47","slug":"recirculated-wave-undulators-for-compact-fels","status":"publish","type":"publications","link":"https:\/\/www.clpu.es\/en\/publications\/recirculated-wave-undulators-for-compact-fels\/","title":{"rendered":"Recirculated wave undulators for compact FELs"},"content":{"rendered":"<p>Particular schemes of Free Electron Lasers (FELs) are designed to exploit wave undulators. We consider a system employing a recirculated electromagnetic undulator provided by a high-power laser in a resonator cavity. The aim is to establish from calculations a set of realizable parameters for such a device. Indeed, novel generation electron accelerators push forward the limits on the accelerating fields, reducing to the sub-meter scale the length over which the electrons can gain enough energy for lasing in the VUV\/X-ray region of the electromagnetic spectrum. On the other hand, these innovative technologies do not solve yet the problem associated with the saturation length and therefore of the undulator length, which can be as long as several tens of meters. The option of a FEL based on a wave undulator might provide a valid solution in this respect<\/p>\n","protected":false},"author":2,"featured_media":0,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"a_os":[35],"class_list":["post-5678","publications","type-publications","status-publish","hentry","a_os-35","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Recirculated wave undulators for compact FELs - CLPU<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.clpu.es\/publications\/recirculated-wave-undulators-for-compact-fels\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Recirculated wave undulators for compact FELs - CLPU\" \/>\n<meta property=\"og:description\" content=\"Particular schemes of Free Electron Lasers (FELs) are designed to exploit wave undulators. We consider a system employing a recirculated electromagnetic undulator provided by a high-power laser in a resonator cavity. The aim is to establish from calculations a set of realizable parameters for such a device. Indeed, novel generation electron accelerators push forward the&hellip; Continue reading Recirculated wave undulators for compact FELs\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.clpu.es\/publications\/recirculated-wave-undulators-for-compact-fels\/\" \/>\n<meta property=\"og:site_name\" content=\"CLPU\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-03T08:50:47+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.clpu.es\\\/publications\\\/recirculated-wave-undulators-for-compact-fels\\\/\",\"url\":\"https:\\\/\\\/www.clpu.es\\\/publications\\\/recirculated-wave-undulators-for-compact-fels\\\/\",\"name\":\"Recirculated wave undulators for compact FELs - CLPU\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.clpu.es\\\/#website\"},\"datePublished\":\"2022-01-03T12:01:48+00:00\",\"dateModified\":\"2025-02-03T08:50:47+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.clpu.es\\\/publications\\\/recirculated-wave-undulators-for-compact-fels\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.clpu.es\\\/publications\\\/recirculated-wave-undulators-for-compact-fels\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.clpu.es\\\/publications\\\/recirculated-wave-undulators-for-compact-fels\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/www.clpu.es\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Publications\",\"item\":\"https:\\\/\\\/www.clpu.es\\\/publications\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Recirculated wave undulators for compact FELs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.clpu.es\\\/#website\",\"url\":\"https:\\\/\\\/www.clpu.es\\\/\",\"name\":\"CLPU\",\"description\":\"Centro de L\u00e1seres Pulsados\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.clpu.es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Recirculated wave undulators for compact FELs - CLPU","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.clpu.es\/publications\/recirculated-wave-undulators-for-compact-fels\/","og_locale":"en_US","og_type":"article","og_title":"Recirculated wave undulators for compact FELs - CLPU","og_description":"Particular schemes of Free Electron Lasers (FELs) are designed to exploit wave undulators. We consider a system employing a recirculated electromagnetic undulator provided by a high-power laser in a resonator cavity. The aim is to establish from calculations a set of realizable parameters for such a device. Indeed, novel generation electron accelerators push forward the&hellip; Continue reading Recirculated wave undulators for compact FELs","og_url":"https:\/\/www.clpu.es\/publications\/recirculated-wave-undulators-for-compact-fels\/","og_site_name":"CLPU","article_modified_time":"2025-02-03T08:50:47+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.clpu.es\/publications\/recirculated-wave-undulators-for-compact-fels\/","url":"https:\/\/www.clpu.es\/publications\/recirculated-wave-undulators-for-compact-fels\/","name":"Recirculated wave undulators for compact FELs - CLPU","isPartOf":{"@id":"https:\/\/www.clpu.es\/#website"},"datePublished":"2022-01-03T12:01:48+00:00","dateModified":"2025-02-03T08:50:47+00:00","breadcrumb":{"@id":"https:\/\/www.clpu.es\/publications\/recirculated-wave-undulators-for-compact-fels\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.clpu.es\/publications\/recirculated-wave-undulators-for-compact-fels\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.clpu.es\/publications\/recirculated-wave-undulators-for-compact-fels\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.clpu.es\/en\/"},{"@type":"ListItem","position":2,"name":"Publications","item":"https:\/\/www.clpu.es\/publications\/"},{"@type":"ListItem","position":3,"name":"Recirculated wave undulators for compact FELs"}]},{"@type":"WebSite","@id":"https:\/\/www.clpu.es\/#website","url":"https:\/\/www.clpu.es\/","name":"CLPU","description":"Centro de L\u00e1seres Pulsados","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.clpu.es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.clpu.es\/en\/wp-json\/wp\/v2\/publications\/5678","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.clpu.es\/en\/wp-json\/wp\/v2\/publications"}],"about":[{"href":"https:\/\/www.clpu.es\/en\/wp-json\/wp\/v2\/types\/publications"}],"author":[{"embeddable":true,"href":"https:\/\/www.clpu.es\/en\/wp-json\/wp\/v2\/users\/2"}],"wp:attachment":[{"href":"https:\/\/www.clpu.es\/en\/wp-json\/wp\/v2\/media?parent=5678"}],"wp:term":[{"taxonomy":"a_os","embeddable":true,"href":"https:\/\/www.clpu.es\/en\/wp-json\/wp\/v2\/a_os?post=5678"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}