{"id":42761,"date":"2025-11-12T07:36:25","date_gmt":"2025-11-12T07:36:25","guid":{"rendered":"https:\/\/www.clpu.es\/?post_type=publications&#038;p=42761"},"modified":"2025-11-12T07:37:19","modified_gmt":"2025-11-12T07:37:19","slug":"characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients","status":"publish","type":"publications","link":"https:\/\/www.clpu.es\/en\/publications\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\/","title":{"rendered":"Characterization of commercial EJ-212 PVT scintillators as proton beam diagnostics. Luminescent study &#038; Birks coefficients."},"content":{"rendered":"<p>Plastic scintillators exhibit great versatility in radiation detection, making them essential diagnostic tools in numerous scientific areas. Their application in characterizing charged particle beams \u2013 whether from particle accelerators or laser-plasma interactions \u2013 is particularly common. However, the detailed processes that govern their luminescence are still being studied, primarily due to the structural complexity of the organic macro-molecules that constitute them. Moreover, precise calibration is crucial for accurately determining incident particle flux \u2013 whether from photons or charged particles \u2013 which is vital for exact dose calculations. This paper investigates the luminescent properties of the plastic scintillator EJ-212 from Eijen by irradiating it with monoenergetic pulsed proton beams using a spectrometer. The Birks coefficients, which indicate the number of luminescent photons produced per incident particle, were obtained by directly capturing the luminescence images with a CMOS camera coupled to a standard objective. Additionally, Monte Carlo simulations were conducted to evaluate the energy deposited by protons as a function of penetration depth for energies ranging from 2 to 8 MeV.<\/p>\n","protected":false},"author":1,"featured_media":0,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"a_os":[160],"class_list":["post-42761","publications","type-publications","status-publish","hentry","a_os-160","entry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Characterization of commercial EJ-212 PVT scintillators as proton beam diagnostics. Luminescent study &amp; Birks coefficients. - CLPU<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.clpu.es\/publications\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Characterization of commercial EJ-212 PVT scintillators as proton beam diagnostics. Luminescent study &amp; Birks coefficients. - CLPU\" \/>\n<meta property=\"og:description\" content=\"Plastic scintillators exhibit great versatility in radiation detection, making them essential diagnostic tools in numerous scientific areas. Their application in characterizing charged particle beams \u2013 whether from particle accelerators or laser-plasma interactions \u2013 is particularly common. However, the detailed processes that govern their luminescence are still being studied, primarily due to the structural complexity of&hellip; Continue reading Characterization of commercial EJ-212 PVT scintillators as proton beam diagnostics. Luminescent study &#038; Birks coefficients.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.clpu.es\/publications\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\/\" \/>\n<meta property=\"og:site_name\" content=\"CLPU\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-12T07:37:19+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.clpu.es\\\/publications\\\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\\\/\",\"url\":\"https:\\\/\\\/www.clpu.es\\\/publications\\\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\\\/\",\"name\":\"Characterization of commercial EJ-212 PVT scintillators as proton beam diagnostics. Luminescent study & Birks coefficients. - CLPU\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.clpu.es\\\/#website\"},\"datePublished\":\"2025-11-12T07:36:25+00:00\",\"dateModified\":\"2025-11-12T07:37:19+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.clpu.es\\\/publications\\\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.clpu.es\\\/publications\\\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.clpu.es\\\/publications\\\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/www.clpu.es\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Publications\",\"item\":\"https:\\\/\\\/www.clpu.es\\\/publications\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Characterization of commercial EJ-212 PVT scintillators as proton beam diagnostics. Luminescent study &#038; Birks coefficients.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.clpu.es\\\/#website\",\"url\":\"https:\\\/\\\/www.clpu.es\\\/\",\"name\":\"CLPU\",\"description\":\"Centro de L\u00e1seres Pulsados\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.clpu.es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Characterization of commercial EJ-212 PVT scintillators as proton beam diagnostics. Luminescent study & Birks coefficients. - CLPU","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.clpu.es\/publications\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\/","og_locale":"en_US","og_type":"article","og_title":"Characterization of commercial EJ-212 PVT scintillators as proton beam diagnostics. Luminescent study & Birks coefficients. - CLPU","og_description":"Plastic scintillators exhibit great versatility in radiation detection, making them essential diagnostic tools in numerous scientific areas. Their application in characterizing charged particle beams \u2013 whether from particle accelerators or laser-plasma interactions \u2013 is particularly common. However, the detailed processes that govern their luminescence are still being studied, primarily due to the structural complexity of&hellip; Continue reading Characterization of commercial EJ-212 PVT scintillators as proton beam diagnostics. Luminescent study &#038; Birks coefficients.","og_url":"https:\/\/www.clpu.es\/publications\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\/","og_site_name":"CLPU","article_modified_time":"2025-11-12T07:37:19+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.clpu.es\/publications\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\/","url":"https:\/\/www.clpu.es\/publications\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\/","name":"Characterization of commercial EJ-212 PVT scintillators as proton beam diagnostics. Luminescent study & Birks coefficients. - CLPU","isPartOf":{"@id":"https:\/\/www.clpu.es\/#website"},"datePublished":"2025-11-12T07:36:25+00:00","dateModified":"2025-11-12T07:37:19+00:00","breadcrumb":{"@id":"https:\/\/www.clpu.es\/publications\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.clpu.es\/publications\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.clpu.es\/publications\/characterization-of-commercial-ej-212-pvt-scintillators-as-proton-beam-diagnostics-luminescent-study-briks-coefficients\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.clpu.es\/en\/"},{"@type":"ListItem","position":2,"name":"Publications","item":"https:\/\/www.clpu.es\/publications\/"},{"@type":"ListItem","position":3,"name":"Characterization of commercial EJ-212 PVT scintillators as proton beam diagnostics. Luminescent study &#038; Birks coefficients."}]},{"@type":"WebSite","@id":"https:\/\/www.clpu.es\/#website","url":"https:\/\/www.clpu.es\/","name":"CLPU","description":"Centro de L\u00e1seres Pulsados","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.clpu.es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.clpu.es\/en\/wp-json\/wp\/v2\/publications\/42761","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.clpu.es\/en\/wp-json\/wp\/v2\/publications"}],"about":[{"href":"https:\/\/www.clpu.es\/en\/wp-json\/wp\/v2\/types\/publications"}],"author":[{"embeddable":true,"href":"https:\/\/www.clpu.es\/en\/wp-json\/wp\/v2\/users\/1"}],"wp:attachment":[{"href":"https:\/\/www.clpu.es\/en\/wp-json\/wp\/v2\/media?parent=42761"}],"wp:term":[{"taxonomy":"a_os","embeddable":true,"href":"https:\/\/www.clpu.es\/en\/wp-json\/wp\/v2\/a_os?post=42761"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}